ASTM D5321 PDF

Interface Shear Instructions: ASTM D OR. ASTM D 1. Test Type. Isolated Interface. Multiple Interfaces (“floating”) – skip to “3” below. 2. Shear Plane. ASTM D/DM: Standard Test Method for Determining the Shear Strength of Soil-Geosynthetic and Geosynthetic-Geosynthetic Interfaces by Direct . ASTM D/DM Standard Test Method for Determining the Shear Strength of Soil-Geosynthetic and Geosynthetic-Geosynthetic.

Author: Goltir Faugul
Country: Trinidad & Tobago
Language: English (Spanish)
Genre: Video
Published (Last): 4 March 2011
Pages: 105
PDF File Size: 16.45 Mb
ePub File Size: 19.29 Mb
ISBN: 925-2-38079-656-3
Downloads: 64335
Price: Free* [*Free Regsitration Required]
Uploader: Shaktizil

The test specimens and conditions, including normal stresses, are generally selected by the user. Results obtained from this method may be limited in their applicability to the specific conditions considered in the testing. In cases of dispute, comparative tests to determine whether a statistical bias exists among laboratories may be advisable. Geosynthetic testing Back to Results Print. The user of results from this test method is cautioned that results at a specified displacement may not be reproducible across laboratories and that the relative shear displacement measured in this test at peak strength may not match relative shear displacement at peak strength in a field condition.

The test data are presented by a best fit straight line whose slope is the coefficient of friction between the two materials where the shearing occurred. The y-intercept of the straight line is the adhesion.

  AIPS COOKBOOK PDF

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided d531 part of the standard. Combining values from the two systems may result in nonconformance with the standard. The normal loads used typically at least three normally represent asttm conditions. Testing under this test method should be performed by laboratories qualified in the direct zstm testing of soils and meeting the requirements of Practice Despecially since the test results may depend on site-specific and test conditions.

Every effort should be made to identify, as closely as practicable, the sheared area and failure mode of the specimen. The total shear resistance may be a combination of sliding, rolling, and interlocking of material components.

Request Quote Client Login. The determined value may be a function of the applied normal stress, material characteristics for example, of the geosyntheticsoil properties, size of sample, moisture content, drainage conditions, displacement rate, magnitude of displacement, and other parameters.

ASTM D Archives | Geosynthetica: Geosynthetics Engineering

For more information, contact: The shear force is recorded with respect to displacement. A shear force is applied to the apparatus such that one section of the box is moved in relation to the other.

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. For Individuals with needing special assistance for disabilities or limited English proficiency Please contact our Title VI specialist at Geosynthetic satm Lab Services: In the case of acceptance testing requiring the use of soil, the user must furnish the soil sample, soil parameters, and direct shear test parameters.

  HEATRONIC 3 PDF

Shear resistance between a geosynthetic and a soil, or a geosynthetic and another geosynthetic is measured.

The geosynthetic and other asstm is placed within a large-scale direct shear box with an applied normal load on top. Link to Active This link will always route to the current Active version of the standard. Historical Version s – view previous versions of standard.

Care should be taken, including close visual inspection of the specimen after testing, to ensure that the testing conditions are representative of those being investigated.

Active Risk Management

The peak and post-peak shear stresses are plotted against the applied normal stresses. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the asym of regulatory limitations prior to use.

The method of test data interpretation for purposes of acceptance should be mutually agreed to by the users of this test method.