ASTM D6693 PDF

GeoTesting Express is a provider of Geosynthetic Testing Services – ASTM D,Standard Test Method for Determining Tensile Properties of Nonreinforced. ASTM D (D) determines the tensile properties of nonreinforced geomembranes in the form of standard dumbbell-shaped test specimens when tested. Buy ASTM D R TEST METHOD FOR DETERMINING TENSILE PROPERTIES OF NONREINFORCED POLYETHYLENE AND.

Author: Tasho Brabei
Country: Mayotte
Language: English (Spanish)
Genre: Art
Published (Last): 9 February 2004
Pages: 141
PDF File Size: 12.63 Mb
ePub File Size: 17.35 Mb
ISBN: 301-3-80656-962-8
Downloads: 83899
Price: Free* [*Free Regsitration Required]
Uploader: Vum

Active Risk Management

This sensitivity to rate of straining and environment necessitates testing over a broad load-time scale and range of environmental conditions if tensile properties are to suffice for engineering design purposes. Hence, where directly comparable results are desired, all samples should be of equal thickness. Referenced Documents purchase xstm The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Link to Active This link will always route to the current Active version of the standard.

ASTM D Tensile Test of Geomembranes

Link to Active This link will always route to the current Active version of the standard. Hence, when comparative tests of materials are desired, the care must be exercised to ensure that all samples are prepared in exactly the same way, unless the test is to include the effects of sample preparation. Further, it is realized that variations in the aetm of test specimen, as permitted by this test standard, produce variations in the surface-volume ratios of such specimens, and that these variations may influence the test results.

Combining values from the two systems may result in non-conformance with the standard.

  HERCULINE BARBIN PDF

Special additional tests should be used where more precise physical data are needed. Therefore, it is advisable to refer to that material’s specification before using this test method. A wide difference may exist between the rate of crosshead movement and the rate of strain of the specimen indicating that the testing speeds specified may disguise important effects or characteristics of these materials in the plastic state.

ASTM D6693 Tensile Test of Geomembranes

This test method is not intended to cover precise physical procedures. The constant rate of crosshead movement of this test lacks accuracy from a theoretical standpoint. Active view current version of standard. Noteā€”This test method is not intended to cover precise physical procedures.

Hence, where directly comparable results are desired, all samples should be of equal thickness. Historical Version s – view previous versions of standard. Consequently, where precise comparative results are desired, these factors must be carefully monitored and controlled.

These data are also useful for qualitative characterization and for research and development. The values given in parentheses are for information only. It may be necessary to modify this procedure for use in testing certain materials as recommended by the material specifications.

The values stated in each d66993 may not be exact equivalents; therefore, each system shall be used independently of the other.

Similarly, for referee purposes or comparisons within any given series of specimens, care must be taken to secure the maximum degree of uniformity in details of preparation, treatment, and handling.

Special additional tests should be used where more precise physical data are needed. Further, it is realized that variations in the thicknesses of test specimens, as permitted by this test method, produce variations in the surface-volume ratios of such specimens, and that these variations may influence the test results. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

  ISTORIA RELIGIILOR ELIADE PDF

However, because of the high degree of sensitivity exhibited by many plastics to rate of straining and environmental conditions, data obtained by this test method cannot be considered valid for applications involving load-time scales or environments widely different from those of this test method.

In cases of such dissimilarity, no reliable estimation of the limit of usefulness can be made for most plastics.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Tensile properties may provide useful data for plastics engineering design purposes. The constant rate of crosshead movement of this test lacks accuracy from a theoretical standpoint. A wide difference may exist between the rate of crosshead movement and the rate of strain of the specimen indicating that the testing speeds d693 may disguise important effects or characteristics of these materials in the plastic state.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.